Pilon Locking Plates System (PLS)
The ITS. Pilon Locking Plate is a proven osteosynthesis system designed for the effective treatment of various pilon fractures.
A special feature of this system is the freely selectable hole configuration, which makes it possible to choose locking or non-locking screws for each hole (except compression and oblong holes). With an angle selection of +/- 15°, the system offers particular versatility, especially for complex fractures.
- Multi-directional Locking
- Anatomical Plate Design
- 6 distal plate holes for optimal fixation close to joint
- K-Wire holes for preliminary plate fixation
- Pointed proximal plate end for percutaneous insertion
- Plate lengths: 4, 6, 8, 10-hole
- Plate strength: 4.0mm
Fibula Locking Plate (FL)
The ITS. Fibula Locking Plate is a trusted osteosynthesis system for treating a wide range of distal fibula fractures.
A special feature of this system is the freely selectable hole configuration, which makes it possible to choose locking or non-locking screws for each hole (except compression and oblong holes). With an angle selection of +/- 15°, the system offers particular versatility, especially for complex fractures.
- Multi-directional Locking
- Anatomically shaped
- Oblong hole for optimal positioning and alignment of the fibula length
- Pointed proximal plate end for percutaneous insertion
- Left/right version
- Plate lengths: 4, 6, 8, 10, 12-hole
Calcaneus Locking Plates (CALmi & CAL)
The ITS. Anterolateral Calcaneus Locking Plate (CALmi) and the ITS. Calcaneus Locking Plate (CAL) are proven osteosynthesis systems for treating a wide range of calcaneus fractures.
A special feature of both systems is the freely selectable hole configuration, which makes it possible to choose between locking and non-locking screws for each hole (except compression and oblong holes). With an angle selection of +/- 15°, they offer particular versatility, especially for complex fractures.
- Multi-directional Locking
- Anatomical plate design
- Short plate version located directly under the subtalar joint (small and large)
- Long plate version located directly under the subtalar joint with an extension to posterior tubercle (small and large)
- Plate insertion through a sinus tarsi incision
- K-Wire holes for temporary fixation
- Multiple fixation possibilities for the subcondral support of the anterior, middle and posterior articular surfaces
- For minimally invasive access in complex calcaneal fractures
- Multiple proximal plate holes to gain proper fixation in the sustentaculum tali
- 4 plate version for the left and the right calcaneus
- Multi-directional Locking
- Anatomical plate design
- Option of in situ bending
- Short and long version
Calcaneus Distractor & Heel Press
Specifically designed for the precise repositioning and fixation of calcaneus fractures, ITS. offers the Calcaneus Distractor & Heel Press, which provides an efficient method to ensure intraoperative stability and optimize anatomical reconstruction.
Features:
- Precise repositioning
- Variable pressure regulation
- Multifunctional use (open and closed repositioning)
Hallux Osteotomy Locking Plate (HOL)
The Hallux Osteotomy Locking Plate from ITS is an intramedullary self-locking plate designed for distal metatarsal osteotomies. As the screw is inserted, the two flanks are splayed out, providing the implant with a secure intramedullary hold.
This implant stands out for its versatility, allowing the selection of your preferred osteotomy technique. It features a straightforward and efficient surgical procedure, ensuring a stable implant position that supports early weight-bearing.
- Multi-directional locking
- Intramedullary locking
- Minimization of soft tissue irritation due to the anatomical plate design
- Free selection of the most common osteotomy techniques
- Primary stability
- Simple surgical procedure
- Brief operation time
- 3 different plate sizes: 8, 9, 10mm
Foot Locking Plates System (FLS)
The ITS. Foot Locking System is a proven osteosynthesis solution offering a variety of plate types to address a wide range of foot fractures.
A special feature of this system is the freely selectable hole configuration, which makes it possible to choose locking or non-locking screws for each hole (except compression and oblong holes). With an angle selection of +/- 15°, the system offers particular versatility, especially for complex fractures.
- Multi-directional locking
- Anatomical plate design
- Minimization of soft tissue irritation due to anatomical plate design
- K-Wire holes for preliminary plate fixation
- FLS Plate Straight, Square, L-Shape, L-Shape Extended, L-Shape Extended 1mm Step, MTP, T-Shape: Sliding hole with compression option (to create tension)
Headless Compression Screws (HCS)
ITS. Headless Compression Screws are available in various diameters and lengths, providing versatile solutions for fracture treatment in trauma and orthopedic surgery.
The innovative headless design reduces soft tissue irritation, making it ideal for minimally invasive fracture fixation.
- Self-drilling & self-tapping
- Cannulated for minimally invasive treatment and guided insertion
- Minimization of soft tissue irritation due to self-tapping grooves at the threaded head
- Special head design for easier countersink of the screw
- Back-tapping flank for easier explantation
- Thread lead difference between head and shaft thread to optimize the fracture or osteotmy compression
- Various diameters for a wide range of indications: 2.0, 2.5, 3.0, 3.5, 4.3, 7.5, 8.5mm
Cannulated Screws (CAS)
ITS. provides various cannulated screw types with different diameters and lengths covering a wide range of indications for fracture treatment in trauma surgery.
Low-profile screw heads with small diameters help minimize soft tissue irritation and are suitable for minimally invasive methods.
We offer customized equipping of surgical trays so that users can have trays put together according to their needs and preferences.
- Self-drilling & self-tapping
- Cannulated for minimal invasive treatment and guided insertion
- Various thread types for a wide range of indications
- Flat and curved washers (adapted to the screw head, for optimal contact to the bone surface)
Twist-Off Screws (TOS)
The ITS. Twist-off Screws provide Precision and Efficiency in Trauma Surgery by allowing for fast and stable fixation, e.g. in the treatment of fractures and corrective osteotomies.
These fully threaded self-tapping and self-drilling screws come in two different diameters (2.0mm and 2.7mm) and a variety of different lengths.
ITS. Twist-off Screws are securely clamped onto a power tool (pin/wire driver), and the new, improved shear-off geometry allows for a smooth break between the shaft and the screw once the screw head engages with the bone cortex.
- Self-drilling & self-tapping
- Fast and stable fixation
- Clamping of the screw directly in the power tool with wire attachment
- Special shear off geometry facilitates a smooth break between shaft and screw at specific torque
Instrument
Inverse Philips Screwdriver
Invers-Phillips-Screwdriver shank for final insertion of the Twist-Off Screw.
The pointed claw edges facilitates the retaining of the screw head as well as the entire explantation.