Clavicle Locking Plates System (CLS)
Plates
Upper Extremity
The ITS. Clavicle family is a proven osteosynthesis system for various fractures of the clavicle. With this technology, an anatomical reduction is achieved and fixed until healing. The short immobilization time ensures rapid rehabilitation and early functionality.
Both a superior and an anterior system are available, both with anatomically shaped medial and lateral plates. In addition, the new Clavicle Hook Locking Plate System (CHLP) provides reliable fixation for fractures of the lateral clavicle and acromioclavicular joint injuries.
Although all plates are anatomically pre-contoured, they can be further contoured intraoperatively, to achieve the best anatomical fit for each individual patient.
Features Anterior Clavicle Locking Plates System (ACLS)
Anterior Clavicle Plate Medial
- Multi-directional Locking
- Anatomical pre-contoured plate design
- Recon Design facilitates individual contouring
- Sliding hole with compression option of up to 7 mm
- Tapered plate ends and edges minimizes soft tissue irritations
Anterior Clavicle Plate Lateral
- Multi-directional Locking
- Anatomical pre-contoured plate design
- Recon Design facilitates individual contouring
- Sliding hole with compression option up to 7mm
- Tapered plate ends and edges minimizes soft tissue irritations
- Staggered & pre-angled plate holes for optimal fixation in the flat lateral area
- 10-hole and lateral variants are adapted to the clavicle in the lateral area in both the horizontal and vertical level
Features Clavicle Locking Plates System (CLS)
Superiore Clavicle Plate Medial
- Turn 180° for right and left versions
- Bridging middle section for additional strength, which covers the breaking point
- Two strengths
Superiore Clavicle Plate Lateral
- L & R Version
- Wide lateral section for holding several screws
- Pointed medial plate end for percutaneous insertion (long plate)
Superiore Clavicle Plate Lateral Narrow
- Anatomically contoured
- Lateral 25% narrower
- Waisted shape
- Smaller holes in lateral area to accomodate greater number of screws
Features Clavicle Hook Locking Plate (CHLP)
Clavicle Hook Plate
- 3 hook depths: 12mm, 16mm, 20mm
- Oblong hole for up to 3.5mm compression
- Increased hook cross section for maximum stregnth
- Hook angle and position designed for optimal fit under acromion
- Anatomically curved shaft to align with shape of distal clavicle
- Low profile plate with rounded edges for reduced risk of soft tissue irritation
- Smooth narrowing of plate from distal to the shaft allowing for placement of four distal screws
Plate Technology. ONE Technology for all Implants.
All ITS. plates are made from Titanium Grade 2, whereas the screws are made of a harder titanium alloy. This allows the plates to have only non-threaded holes, which all (with the exception of oblong holes) accept both non-locking and locking screws.