Clavicle Locking Plates System (CLS)
The ITS. Clavicle family is a proven osteosynthesis system for various fractures of the clavicle. With this technology, an anatomical reduction is achieved and fixed until healing. The short immobilization time ensures rapid rehabilitation and early functionality.
Both a superior and an anterior system are offered, each with anatomically shaped medial and lateral plates.
Although all plates are anatomically pre-contoured, they can be further contoured intraoperatively, to achieve the best anatomical fit for each individual patient.
- Multi-directional Locking
- Anatomical plate design
- Recon Design facilitates individual contouring
- Sliding hole with compression option of up to 7mm
- Tapered plate ends and edges minimizes soft tissue irritations
- Multi-directional Locking
- Anatomical plate design
- Recon Design facilitates individual contouring
- Sliding hole with compression option up to 7mm
- Tapered plate ends and edges minimizes soft tissue irritations
- Staggered & pre-angled plate holes for optimal fixation in the flat lateral area
- 10-hole and lateral variants are adapted to the clavicle in the lateral area in both the horizontal and vertical level

- Multi-directional Locking
- Anatomical plate design
- Turn 180° for right and left versions
- Bridging middle section for additional strength, which covers the breaking point
- Plate strengths: 2.5mm und 3.5mm
- Multi-directional Locking
- Anatomical plate design
- L & R Version
- Wide lateral section for holding several screws
- Pointed medial plate end for percutaneous insertion (long plate)
- Multi-directional Locking
- Anatomical plate design
- Lateral 25% narrower
- Waisted shape
- Smaller holes in lateral area to accomodate greater number of screws

Proximal Humeral Locking Plate System Phoenix (PHL PHX)
PHL PHX – Flanges
The ITS. Proximal Humeral Locking System Phoenix – Flanges aims to provide simplified solutions to complex problems. This versatile system enables the treatment of various proximal humeral fractures, with the contourable anterior/posterior flanges facilitating the proper fixation of the entire humeral head.
PHL PHX – Standard
The Proximal Humeral Locking System Phoenix – Standard features a flange-free plate for simple fractures, a wider head with 11 holes, and options for the medial calcar screw. Polyaxial locking technology supports a flexible screw pattern to effectively stabilize the humeral head.
The ITS. Proximal Humeral Locking System Phoenix – Standard features a flange-free plate for simple fractures, a wider head with 11 holes, and options for the medial calcar screw. Polyaxial locking technology supports a flexible screw pattern to effectively stabilize the humeral head.
- 6 marginal proximal holes for rotator cuff fixation or temporary plate fixation
- Multiple holes for optimal proximal screw placement
- Indentations in the shaft area to facilitate the use of cerclage bands and wires
- Oblong hole for optimal positioning and adjustment of the humeral length
- Pointed distal plate end for percutaneous insertion
- Contourable anterior and posterior flanges for better fixation of the greater and lesser tuberosity
- Superior hook flange for capturing greater tuberosity

- 6 marginal proximal holes for rotator cuff fixation or temporary plate fixation
- Multiple holes for optimal proximal screw placement
- Indentations in the shaft area to facilitate the use of cerclage bands and wires
- Oblong hole for optimal positioning and adjustment of the humeral length
- Pointed distal plate end for percutaneous insertion
- Optional Drill Block

Distal Humerual Locking Plates (DHL)
The ITS. Distal Humeral Locking Plates offer a reliable osteosynthesis solution for treating a wide range of distal humerus fractures.
A special feature of this system is the freely selectable hole configuration, which makes it possible to choose locking or non-locking screws for each hole (except compression and oblong holes). With an angle selection of +/- 15°, the system offers particular versatility, especially for complex fractures.
- Multi-directional Locking
- Anatomical plate design
- Sliding hole with compression option up to 4mm
- Pointed proximal plate end for percutaneous insertion
- Left/right version
Lengths: 4, 5, 6, 7-hole

Olecranon Locking Plates (OLS)
The ITS. Olecranon Locking Plates System offers a versatile solution for olecranon fractures, providing stable and precise reconstruction for both simple and complex cases.
Locking plating supports early postoperative mobility, unlike traditional methods like tension banding, which often require extended immobilization. The adjustable screw angles offer greater flexibility, especially in complex fractures.
- Anatomically contoured
- Optimal reconstruction of the joint surface
- Simple positioning due to sliding hole
- Sliding hole with compression option up to 4mm
- 5-hole left/right
- 7, 9-hole left & right
- Anatomically contoured
- Optimal reconstruction of the joint surface
- Simple positioning due to sliding hole
- Oblong hole for optimal positioning and adjustment of ulna length
- Lengths: 6, 8, 10, 12-hole

Straight Locking Plates System (SLS)
ITS. offers a versatile selection of Straight Locking Plates, available in multiple strengths and lengths to accommodate a wide range of shaft fracture indications.
A special feature of this system is the freely selectable hole configuration, which makes it possible to choose locking or non-locking screws for each hole (except compression and oblong holes). With an angle selection of +/- 15°, the system offers particular versatility, especially for complex fractures.
- Multi-directional Locking
- Anatomical plate design
- Accurate fitting of the plate on the bone
Plate lengths: 4, 5, 6, 7, 8, 9-hole
Plate lengths: 4, 5, 6, 7, 8, 9, 11, 13-Loch
- Plate lenghts: 5, 6, 7, 8, 9, 10, 11, 12, 13-hole
- Fracture gap compression up to 8mm

Straight Compression Locking Plate (SCL)
The ITS. Straight Compression Locking Plate offers an innovative solution for fracture treatment. An outstanding feature of this implant is the special compression hole, which allows compression of the fracture gap of up to 7mm.
The unique design of the compression hole allows the use of a locking screw set that locks after full compression.
In addition, the plate has notches on the back to protect the periosteum and thus promote healing.
- Multi-directional Locking
- Anatomical plate design
- Indentations on the rear side of the plate for protection of the periosteum
- K-Wire holes for preliminary plate fixation
- Fracture gap compression up to 7mm

Universal Forearm Locking Plates System (UFS)
The ITS. Universal Forearm Locking Plates System is designed for the effective treatment of a wide range of forearm shaft fractures.
A special feature of this system is the freely selectable hole configuration, which makes it possible to choose locking or non-locking screws for each hole (except compression and oblong holes). With an angle selection of +/- 15°, the system offers particular versatility, especially for complex fractures.
- Multi-directional Locking
- Anatomical Plate Design
- Low-profile design
- Straight and curved version adapted to the forearm anatomy
- Guide wire holes for preliminary plate fixation
- Sliding hole with compression option up to 4mm
- Tapered plate ends for a smooth insertion under the soft tissue
- Free choice of plate position (volar, dorsal, radial, ulnar)
- Axial indentations on the rear side of the plate for accurate fitting on the bone
- Plate strength curved: 3.5mm
- Plate strength straight: 3.0mm
- Available in the Plate lengths: 6, 9, 11-hole

PROlock Radius Locking Plate II
The PROlock Radius Locking Plate II is the next-generation distal radius plating system, built on the proven success of the ITS Radius Plates. Available in left and right designs, and in various lengths and widths, it offers tailored solutions for different anatomies.
Its tapered watershed line allows distal plate placement while minimizing tendon irritation. The system features polyaxial locking in all screw holes (except oblong), with pre-angled holes for easy insertion and extended reach. The optional radiolucent drill block aids in precise, rapid screw placement.
- K-wire holes for temporary plate fixation
- Minimization of flexor tendon irritation due to anatomical plate design
- Pre-angled screw holes to facilitate capture of fragments
- Oblong hole for optimal plate positioning
- L & R version and available in different lenghts and widths
- Optional Drill Block

Distal Ulna Locking Plate (DUL)
The ITS. Distal Ulna Locking Plate System is designed for secure fixation with locking screws and can be easily contoured to fit the distal ulna. Positioned palmarly, the plate is naturally covered by the surrounding musculature, often eliminating the need for metal removal.
Locking screws stabilize the ulnar head while the plate configuration supports the transition to the neck area. Using locking screws in the proximal section enhances overall rigidity, ensuring robust and reliable fixation.
- Anatomical plate design
- K-Wire holes for preliminary plate fixation
- Oblong hole for optimal positioning and adjustment of ulna length
- Pointed proximal plate end for percutaneous insertion
- 5 distal plate holes for optimal reconstruction of the distal radioulnar joint (DRUJ)
- Available in L & R / standard & small and in various lengths

Ulna Osteotomy II (UOL II)
The ITS. Ulna Osteotomy Locking Plate II offers an advanced plating system designed to meet the anatomical and biomechanical needs of distal ulna shortening osteotomies. Equipped with both locking and compression screws, this system provides optimal stabilization and precision during surgery.
This all-in-one solution features a unique plane-parallel cross-section, enabling a rotationally stable shortening process with the option for compression. By simplifying the setup, it standardizes multiple surgical steps, improving the consistency and quality of the procedure, and ensuring reliable outcomes.
- Anatomical plate design
- Three holes distal of the osteotomy
- 30% less components for easier handling
- Central compression via the plate axis facilitates the joining of the osteotomy surfaces
- Fixation of the osteotomy by a screw perpendicular to the cutting surface
- Transection aligned proximally for better compression of the distal and proximal osteotomy parts
- Correction of ulnar position relative to the Surgical Technique – unaffected other side up to a maximum of 8mm in one step.